Scansys Ta517 Anterior Segment Analyzer at Latest Price in India
Scansys Anterior Segment Analyzer is fully automated with touch screen operation, comes with easy to use features at an affordable price. We are Importer, Wholesaler & Supplier of Mediworks Scansys TA 517 Anterior Segment Analyzer in India.
Anterior Segment Analyzer | Mediworks Scansys TA 517
Scansys TA517 Anterior Segment Analyzer provides a professional solution for anterior segment diagnosis. It applies Scheimpflug camera which can collect 107520/230400 data points and generates 28/60 cornea tomography images in high resolution.
Scansys can provide a series of topography maps including cornea curvature maps, cornea thickness maps, cornea elevation maps, etc.
Clinical Application
- Keratoconus Diagnosis
Scansys can provide the prevalence of Keratoconus by using the AI algorithm.Further checking the topographic maps to accurately analyze amd diagnose the keratoconus.
- Refractive surgery
Total cornea aberration guides surgeons to evaluate preoperative and postoperative visual quality to ensure patients of best surgery effect.
- IOL Optimization
Specially designed for cataract surgery. It supports clinicians to choose suitable Toric IOL、 Aspheric IOL or Multifocal IOL for patients.
- ICL Surgery Examination
Scansys supports in different angles to collect a high- resolution picture, It also provides White to White, AC depth for ICL surgery.
AI intelligence recommends the diameter of the ICL crystal and gives elevation of the arch.
Overview
AI Keratoconus Diagnosis
This anterior segment analyzer clinically collects a large amount of data from all over the world and introduces AI algorithms to more intelligently determine the possibility of cone disease (KCP) in the current case. (Reference value: KCP, range 0% -100%) The above figure contains the topographic map of Refractive 4 Maps, the axial curvature map of the rear surface, and the trend distribution of the thickness map. These are the key references for judging the keratoconus.
IOL Optimization
Specially designed for the “IOL Optimization”of refractive cataract surgery, The anterior segment analyzer is given the K1, K2, Km, and Astig values of the three types of corneal refractive power (Simk, total corneal power, true net refractive power), and Kappa&Alpha angle, respectively.
It also provides professional data of the total corneal astigmatism aberration, total corneal spherical aberration, and the total corneal irregular astigmatism, and analysis support for solving spherical refractive errors, astigmatism, spherical aberration, and presbyopia in cataract surgery.
Aberration Analysis
This view is a Zernike analysis of the measured corneal front, back and all surface height data, which calculates a factor for each Zernike polynomial term that describes the contribution of this polynomial to the height data.To guide the visual quality analysis of refractive surgery.
Lens Fitting Analysis
Based on the topography maps generated by Scansys,the system can recommend several lenses suitable for patinent’s cornea and simulate the images of patinent’s wearing lenses, the user can judge whether the lens is suitable. This will accelerate the work flow of lens fitting and reduce the number of trials in the actual process
Chamber Angle Analysis
Scansys can calculate a chamber angle value based on the tomography images and its exclusive AOD graph gives a trend analysis for the distance between cornea back surface to iris. It also provides cornea volume, anterior chamber volume and anterior chamber depth calculation. These analyses is helpful to glaucoma diagnosis.
ICL Surgery Examination
Scansys supports in any Angle to collect a high- definition picture, to provide effective data support for ICL surgery.
AI intelligence recommends the diameter of the ICL crystal and gives elevation of the arch.
Selectable 4 Maps
Click on the “Selectable 4 Maps” to open a window contains 4 optional color maps. Corneal thickness and elevation, etc. can be loaded into one of any 4 fields.
With this option, the user can view and print out important topographic maps needed for daily work in one interface.
Form Factor
The chart upper depicts the corneal form factor and the curvature of the anterior and posterior surface of the cornea at the intersection of the radial axis and the four radial directions.
Corneal shape factors include Ecc, E, Q, and P, which can be changed in the “Map and Data Settings” -> “Form Factor Presentation” in the menu bar “Settings” options.
Lens Analysis
Scansys calculates the lens density value for cross section and longitudinal section which is helpful in cataract diagnosis.
Refractive Power
In the key parameter column on the right, we give K1, K2, Km, Astig. These values are obtained in the range of 3mm in diameter of the membrane.
In order to describe in more detail the difference of these values in each diameter range, We give K1, K2, Km, Astig of the axial curvature of the anterior and posterior corneal, anterior surface refractive power, true net refractive power, full corneal refractive power topographic map, the distribution table of various areas from 2mm to 9mm in diameter, and the distribution curve .
The changes of these values in different topographic maps and different diameter ranges are described more intuitively and in detail.
Anterior Segment Analyzer Specification
Collection Mode
Basic | Professional | ||
---|---|---|---|
28 Cornea Tomography Images | 2D/3D Data Collection | Keratometric Power Deviation | (Including basic functions) |
Anterior Chamber Depth | True Net Refractive Power | Cornea Thickness Maps | 60 Cornea Tomography Images |
Total Cornea Power | Refractive Power(Front) | Cornea Curvature/Elevation Maps | – |
Refractive 4 Maps | AI Keratoconus Diagnosis | Chamber Angle Analysis | IOL Calculation |
Aberration Analysis | Pachymetric Distribution | Lens Density Analysis | IOL Optimization |
Refractive Power Distribution | Lens Fitting | Form Factor | – |
Technical Specification
Camera | Digital infrared camera + Scheimpflug digital CCD camera |
Light Source | LED slit |
Scanning Speed | 28 images within 1 second/ 60 images within 2 second/ single image |
Data Points | 107520/230400 |
Work distance | 80 mm |
Corneal topography | 9mm/12mm |
Corneal thickness | 300-900μm |
Anterior chamber depth | 0.8-6 mm |
Diopter | 12-72 D |
White to white | 6-14 mm |
Pupil diameter | 1-10 mm |
Anterior chamber volume | 15-300 mm3 |
Chamber angle | 16-60 ° |
Kappa/Alpha | R(0-3mm) θ(0-360°) |
Work Range | |
---|---|
Front and back | 115 mm |
Left and right | 100 mm |
Up and down | 30 mm |
Power Supply | |
---|---|
Input voltage | 220v/110v±10% |
Input frequency | 50Hz/60Hz |
Power consumption | 2.4 W |
Weight and Size | |
---|---|
Device dimension | 505*345*460 mm |
Device weight | 12 KG |
Package dimension | 660*570*700 mm |
Package weigh | 25 KG |
System Specifications | |
---|---|
PC configuration | i5-8500T 8G 1T+128G 2Gdiscrete graphics |
Display | 1920×1080 23.8inch |
PC system | Windows 10 |